Integrated Power System

Comprehensive power solution including DC Power, Communication Power, UPS, and Emergency Lighting systems, featuring intelligent control, modular design, and high reliability for critical infrastructure.

Looking for a price? Send an inquiry now!

GET A QUOTE

Integrated Power System

1. DC Power System

Intelligent Dual-Circuit Escort • Wide-Voltage Worry-Free Power Supply

High-frequency modular power supply, N+M backup guarding the power lifeline.

  • Flexible Input Configuration: Supports single/dual AC input, with automatic dual-circuit switching.
  • Wide Voltage Adaptability: Wide input voltage range, strong grid compatibility.
  • High Reliability Design: High-frequency switching power technology, modular design, N+1/N+M backup.
  • Convenient Maintenance: Rectifier modules support hot-swapping under power.
  • Intelligent Monitoring: Touch screen operation, optional languages, rich content.

Technical Parameters

DC Power System

Parameter Value
Rated Input Voltage 380VAC±15%
Rated Output Voltage 220VDC, 110VDC
Module Rated Current 10A / 20A / 30A / 40A
Number of Configured Modules ≤16
Noise ≤60dB (at rated)
Voltage Regulation Accuracy ≤±0.5%
Current Regulation Accuracy ≤±0.5%
Peak-to-Peak Ripple Coefficient ≤±1%
Current Sharing Degree ≤3%
Power Factor ≥0.98 (Full load)
Efficiency Peak efficiency ≥93%
Relative Humidity ≤90%
Ambient Temperature -10℃~40℃
Cooling Method Intelligent Air Cooling

2. Communication Power System

Communication power cabinet, wide-range AC/DC, intelligent modular power, multi-functional stability protection

  • Wide Input Range: Universal AC/DC, adaptable to various power supply environments.
  • Multiple Input Modes: Supports single-phase/three-phase, single/dual circuits, automatic/manual switching.
  • Modular Design: Convenient maintenance and expansion, supports hot-swapping.
  • Intelligent Battery Maintenance: Optimized management, extending battery life.
  • Intelligent Diagnosis and Alarm: Fault self-test, audible and visual warning.

Technical Parameters

Communication Power System

Parameter Value
Rated Input Voltage 220VAC/VDC±15%
Rated Output Voltage 48VDC, 36VDC, 24VDC
Module Rated Current 20A / 30A / 40A / 50A
Number of Configured Modules ≤16
Voltage Regulation Accuracy ≤±0.5%
Charger Efficiency (Peak) ≥94%
Maximum Audible Noise (dB) 55
Source Effect 0.10%
Load Effect 0.50%
Standby Power Consumption ≤5W
Parallel Operation Current Imbalance ±5%
Relative Humidity ≤90%
Ambient Temperature -10℃~40℃
Cooling Method Intelligent Air Cooling

3. UPS Power System

Power outage endurance with stable voltage, filtering pollution to protect equipment, providing all-weather power protection for computer and network systems

  • Power Outage Endurance: Configured with batteries, automatically switches to inverter power supply when mains power is interrupted, providing uninterruptible power to maintain normal equipment operation.
  • Stable Voltage: Automatically adjusts fluctuating voltage to ensure stable output.
  • Purified Power: Filters out interference such as harmonics and surges, providing pure power and protecting equipment and data safety.

Technical Parameters

UPS Power System

Category Parameter Value
Capacity Power Rating 3kVA / 5kVA / 6kVA / 8kVA / 10kVA / 15kVA / 20kVA
Input AC Voltage AC220V±25% / AC220V/AC380V±25% / AC380V±25%
DC Voltage DC220V / DC192V / DC110V
Frequency 50Hz±10%
Output AC Voltage AC220V±1%
Frequency 50Hz±0.5%
Waveform Sine wave, 100% linear load harmonic distortion rate < 3%
Power Factor 0.8
Efficiency ≥90%
Transfer Time 0ms
Protection Overload 105%~125%, 10m; 125%~150%, 60s; ≥150%, 1s then bypass
Short Circuit Protected, transfer to bypass
Fault Transfer to bypass, alarm
Environment Operating Temperature -10℃~40℃
Relative Humidity 0%~95%
Noise < 55dB / < 60dB (1m from front)

Note 1: UPS capacity can be customized according to site requirements, e.g., 120kVA, etc.

4. Emergency Lighting System

Automatic emergency switching, starts immediately when main power is cut off, providing all-weather protection for emergency lighting

  • High Reliability: Dual power input, automatically switches when main power is interrupted, ensuring continuous power supply for emergency lighting.
  • High Efficiency and Environmental Protection: High energy conversion efficiency, paired with battery backup, pollution-free and low energy consumption.
  • Convenient Maintenance: Simple structure, intuitive operation, daily maintenance is simple and efficient.

Technical Parameters

Emergency Lighting System

Category Parameter Value
Module Output Rated Output Power 1kVA – 10kVA
Max Parallel Units 12
DC Input Rated Voltage 220VDC
Voltage Range 185VDC – 285VDC
Bypass Input Transfer Time < 4ms
Allowable AC Range 176V – 264VAC
AC Output Rated Voltage 220VAC
Rated Frequency 50Hz
Power Factor 0.8 Lagging
Load Regulation < 1%
Frequency Accuracy 50Hz±1%
Waveform Distortion < 3% (Resistive), < 5% (Non-linear)
Efficiency ≥88% – 90%
Dynamic Response Transient < 5%, Recovery ≤ 60ms
Parallel Imbalance < 5%
Environment Noise (1m) < 45dB – 55dB
Operating Temp -10℃ – 45℃
Humidity 0% – 90% (No condensation)

Reviews